Practical checklists

Battery proposal assumptions checklist

Check battery savings against the customer’s bill, tariff and usage timing, including the Solar Sharer Offer’s 24 kWh daily free-power allowance.

Prepare the right inputs

Collect the intended bill, usage period, import rates, feed-in credit and daily supply charge. Identify grid purchases versus household use and the existing solar configuration before selecting battery assumptions.

Sources: [4][5]

Does free midday power change the baseline?

Yes. The Solar Sharer Offer began on 1 July 2026 in New South Wales, South Australia and south-east Queensland. It is an opt-in offer for eligible households with smart meters, with a three-hour daily free-power window. It is not every customer's tariff or a nationwide free-electricity promise.

The free period covers up to 24 kWh of eligible electricity usage each day. Household use and battery grid charging share that allowance. Check controlled-load exclusions and the charge that applies above the allowance; daily supply charges still apply.

Check how the retailer applies the allowance. EnergyAustralia says its 24 kWh-per-day cap is averaged across the billing period, so lower usage on one day can offset higher usage on another. Do not assume every plan uses a strict daily cut-off.

Before modelling a change, check the customer's full plan: free-window conditions, rates outside it, supply charge and feed-in credit. Compare alternatives separately; do not combine today's tariff with a future plan's free window. Electricity-retailer obligations are distinct from selling solar equipment.

Sources: [6][7][2][3][1]

A practical example

  • Illustrative baseline check: 4 kWh of eligible usage within the free window and daily allowance has $0 usage cost. Applying an assumed 40c/kWh avoided rate would overstate that segment's saving by $1.60. This excludes supply charges and is not a complete battery forecast.
  • Illustrative cap check: 20 kWh of eligible household use plus 8 kWh of battery grid charging in the same free window totals 28 kWh. That is 4 kWh above a single day’s 24 kWh reference. This does not by itself establish a charge: check whether the plan averages the allowance across the billing period and which excess rate applies.
  • Check: demand timing, usable evidence period, generation, storage capacity, losses, exports and whether finance repayments are included in the displayed comparison.
  • Illustrative review: a low winter bill cannot establish a full year of consumption. Record the limitation and request better evidence before presenting a precise annual outcome.

Sources: [2][3][1]

Keep these boundaries clear

This checklist does not certify design, compatibility or payback. ArcSolar's documentation supports reviewed tariff inputs, manual bill rates and an omit-savings option; it does not establish automatic Solar Sharer Offer modelling. If the exact tariff cannot be represented reliably, resolve the gap or omit the savings figure.

Sources: [4][5]

Put the checklist to work

Bring the customer’s bill, current plan and proposed battery schedule to the demo. Compare the baseline with the issued assumptions and confirm which gaps still need review.

Sources and review (7)

Published by ArcSolar. Examples are illustrative; product details come from the sources below. Editorial standards.

Put the workflow to work.

Review one battery offer in ArcSolar

Book a demo